This machine is appropriate for micro induction motor like conditioner motor, washer motor, compressor motor, fan motor, alternator motor, pump motor etc. The forming for external of coil adopts sliding block folding to restrict the diameter, while the inner block to make the internal coil diameter reach requirement. The head coil forming will be processed after the forming of internal and external of coil completed. This machine has advantages of mature and advanced technology, reliable quality, easy operation and maintenance.
Technical parameter:
Item | Unit | Data |
Size | mm | (L)650×(W)950×(H)2300 |
Tooling included weight | kg | Around 700 |
Power supply | 380V/50Hz three phase four wire power | |
Working pitch time | S/PC | ≤13 |
ID | mm | Φ30~Φ120 |
OD | mm | Φ50~Φ160 |
Stack height | mm | 15~160 |
Tooling stroke | mm | ≤70 |
Machine operation steps
1. After connected to the power source and air source, switch the button to on. Press hydraulic start button; switch to auto mode.
3. Press "reset" button. Check if all parts are in the correct position.
4. Put stator into the groove. Press "Start" button by two hands. Machine will auto form.
Note: there are two triangle blocks (diagonal line) in the groove. The two holes on the stator should be aligned to the two triangle blocks separately.
Caution
1.This machine can not disassemble optionally.
2.If coil dimension and appearance is inaccurate, stop to do adjustment to avoid quality accident.
3.The machine should be stopped or power off when the operator is away or do clean and lubricating job.
4.The safety device can not be removed in the process of using.
5.The dress of operator should meet the safety requirements, stand in proper position.
6.Regularly clean the lubricating tooling and lubricating system. Do not keep the safety door and oil eye lid to avoid of that foreign matter like dust, metal scrap get in.
7.Do not operate the machine if there is a warning sign "Operation prohibited" on the machine until alert relieved.
8.Do not operate the machine when it is under maintenance. Stop the mechanical operation and cut off the power.
9.Operator should not touch electrical parts by wet hands, which may cause electric shock.
10.The operator can not leave away when the machine is running, should keep eyes on that if any abnormality(abnormal noise, unusual smell, over heat, vibration) of each parts coming up. Stop and check the machine immediately if any of above mentioned takes place, and solve it in time.
11.It is prohibited that to use the machine beyond its capacity and load.
12.After stop using the machine, please check and clean up, please do not use the steam, water or corrosive liquid to clean the machine.
The forming process of this forming machine